ACTH ELISA kit (Mouse)

Category: Assay Kits
Catalog
CEA836Mu
(Ships in 5-10 business days)

Questions? Contact us

Call (800) 832-2611

arp-guarantee
- +
$0.00
More Information
Product Name ACTH ELISA kit (Mouse)
Description This assay has high sensitivity and excellent specificity for detection of Adrenocorticotropic Hormone (ACTH). No significant cross-reactivity or interference between Adrenocorticotropic Hormone (ACTH) and analogues was observed.
Synonyms Corticotropin; Adrenocorticotropin
Method Competitive
Detection Range 12.35-1,000pg/mL
Sensitivity 4.94pg/mL
Target ACTH
Specificity This assay has high sensitivity and excellent specificity for detection of Adrenocorticotropic Hormone (ACTH). No significant cross-reactivity or interference between Adrenocorticotropic Hormone (ACTH) and analogues was observed.
Reactivity Mouse
Sample Types Serum, Plasma And Other Biological Fluids
Reconstitution 1.Prepare all reagents, samples and standards; 2.Add 50uL standard or sample to each well. And then add 50uL prepared Detection Reagent A immediately. Shake and mix.Incubate 1 hour at 37℃; 3.Aspirate and wash 3 times; 4.Add 100uL prepared Detection Reagent B.Incubate 30 minutes at 37℃; 5.Aspirate and wash 5 times; 6.Add 90uL Substrate Solution.Incubate 10-20 minutes at 37℃; 7.Add 50uL Stop Solution.Read at 450 nm immediately.
Storage 4°C for 1 month/ -20°C for long-term(within shelf life)
Notes Colormetric
References Ursolic acid suppresses growth and adrenocorticotrophic hormone secretion in AtT20 cells as a potential agent targeting adrenocorticotrophic hormone-producing pituitary adenoma.;High activity of the stress promoter contributes to susceptibility to stress in the tree shrew;Activation of ATP-sensitive potassium channel by iptakalim normalizes stress-induced HPA axis disorder and depressive behaviour by alleviating inflammation and oxidative stress in mouse hypothalamus.;;Triptolide suppresses growth and hormone secretion in murine pituitary corticotroph tumor cells via NF-kappaB signaling pathway;Vaccinium bracteatum Leaf Extract Reverses Chronic Restraint Stress-Induced Depression-Like Behavior in Mice: Regulation of Hypothalamic-Pituitary …;Metformin suppresses growth and adrenocorticotrophic hormone secretion in mouse pituitary corticotroph tumor AtT20 cells;Chronic hippocampal abnormalities and blunted HPA axis in an animal model of repeated unpredictable stress;Comparison between men and women of volume regulating hormones and aquaporin-2 excretion following graded central hypovolemia;Mice lacking Casp1, Ifngr and Nos2 genes exhibit altered depressive-and anxiety-like behaviour, and gut microbiome composition;Hypothalamus-pituitary-adrenal axis imbalance and inflammation contribute to sex differences in separation-and restraint-induced depression;Repeated unpredictable stress and social isolation induce chronic HPA axis dysfunction and persistent abnormal fear memory;Altered glucocorticoid metabolism represents a feature of macroph‐aging;Exposure to eagle owl feces induces anti-predator behavior, physiology, and hypothalamic gene responses in a subterranean rodent, the plateau zokor (Eospalax …;
Supplier Cloud Clone

PROTOCOLS:

All Research Products are sold for laboratory RESEARCH USE ONLY and ARE NOT TO BE USED FOR HUMAN OR ANIMAL THERAPEUTIC OR DIAGNOSTIC APPLICATIONS. The information presented is believed to be accurate; however, said information and products are offered without warranty or guarantee since the ultimate conditions of use and the variability of the materials treated are beyond our control. Nothing disclosed herein is to be construed as a recommendation to use our products in violation of any patents. ARP American Research Products, Inc. does not submit its products for regulatory review by any government body or other organization, and we do not validate them for clinical, therapeutic or diagnostic use, or for safety and effectiveness. You are solely responsible for making sure that the way you use the products complies with applicable laws, regulations and governmental policies and for obtaining all necessary approvals, intellectual property rights, licenses and permissions that you may need related to your use. Under no circumstances shall ARP American Research Products, Inc. be liable for damages, whether consequential, compensatory, incidental or special, strict liability or negligence, breach of warranty or any other theory arising out of the use of the products available from ARP American Research Products, Inc. Nothing contained herein warrants that the use of the products will not infringe on the claims of any patents covering the product itself or the use thereof in combination with other products or in the operation of any process. ARP American Research Products, Inc. disclaims any and all representations or warranties of any kind whatsoever, express or implied, including without limitation any implied warranties of merchantability or fitness for a particular purpose, of non-infringement, or regarding results obtained through the use of any product, whether arising from a statute or otherwise in law or from a course of performance, dealing or usage of trade.