CRP ELISA kit (Human)

Category: Assay Kits
Catalog
HEA821Hu
(Ships in 5-10 business days)

Questions? Contact us

Call (800) 832-2611

arp-guarantee
- +
$0.00
More Information
Product Name CRP ELISA kit (Human)
Description This assay has high sensitivity and excellent specificity for detection of High Sensitive C Reactive Protein (CRP). No significant cross-reactivity or interference between High Sensitive C Reactive Protein (CRP) and analogues was observed.
Synonyms C-RP; PTX1; Pentraxin-Related; Pentraxin 1
Method Sandwich
Detection Range 62.5-4,000pg/mL
Sensitivity 24.3pg/mL
Target CRP
Specificity This assay has high sensitivity and excellent specificity for detection of High Sensitive C Reactive Protein (CRP). No significant cross-reactivity or interference between High Sensitive C Reactive Protein (CRP) and analogues was observed.
Reactivity Human
Sample Types Serum, Plasma, Tissue Homogenates, Cell Lysates, Urine, Cerebrospinal Fluid, Cell Culture Supernates And Other Biological Fluids
Reconstitution 1.Prepare all reagents, samples and standards; 2.Add 100uL standard or sample to each well.Incubate 2 hours at 37℃; 3.Aspirate and add 100uL prepared Detection Reagent A.Incubate 1 hour at 37℃; 4.Aspirate and wash 3 times; 5.Add 100uL prepared Detection Reagent B.Incubate 30 minutes at 37℃; 6.Aspirate and wash 5 times; 7.Add 90uL Substrate Solution.Incubate 10-20 minutes at 37℃; 8.Add 50uL Stop Solution.Read at 450nm immediately.
Uniprot P02741
Storage 4°C for 1 month/ -20°C for long-term(within shelf life)
Notes Colormetric
References Olive (Olea europaea L.) Leaf Polyphenols Improve Insulin Sensitivity in Middle-Aged Overweight Men: A Randomized, Placebo-Controlled, Crossover Trial;Relationships among serum C-reactive protein, receptor for advanced glycation products, metabolic dysfunction, and cognitive impairments;Among overweight middle-aged men, first-borns have lower insulin sensitivity than second-borns;Effect of caffeic acid on doxorubicin induced cardiotoxicity in rats;Effect of high free fatty acids on the anti-contractile response of perivascular adipose tissue in rat aorta;Anti-atherosclerosis and cardio-protective effects of the Angong Niuhuang Pill on a high fat and vitamin D3 induced rodent model of atherosclerosis.;The effects of non-surgical periodontal treatment on glycemic control, oxidative stress balance and quality of life in patients with type 2 diabetes: A randomized clinical trial;Validation and adaptation of the Empirical Dietary Inflammatory Pattern (EDIP) across nations: a test case.;Prevalence and Factors Associated with Iron Deficiency and Anemia among Residents of Urban Areas of S?o Paulo, Brazil;
Supplier Cloud Clone

PROTOCOLS:

All Research Products are sold for laboratory RESEARCH USE ONLY and ARE NOT TO BE USED FOR HUMAN OR ANIMAL THERAPEUTIC OR DIAGNOSTIC APPLICATIONS. The information presented is believed to be accurate; however, said information and products are offered without warranty or guarantee since the ultimate conditions of use and the variability of the materials treated are beyond our control. Nothing disclosed herein is to be construed as a recommendation to use our products in violation of any patents. ARP American Research Products, Inc. does not submit its products for regulatory review by any government body or other organization, and we do not validate them for clinical, therapeutic or diagnostic use, or for safety and effectiveness. You are solely responsible for making sure that the way you use the products complies with applicable laws, regulations and governmental policies and for obtaining all necessary approvals, intellectual property rights, licenses and permissions that you may need related to your use. Under no circumstances shall ARP American Research Products, Inc. be liable for damages, whether consequential, compensatory, incidental or special, strict liability or negligence, breach of warranty or any other theory arising out of the use of the products available from ARP American Research Products, Inc. Nothing contained herein warrants that the use of the products will not infringe on the claims of any patents covering the product itself or the use thereof in combination with other products or in the operation of any process. ARP American Research Products, Inc. disclaims any and all representations or warranties of any kind whatsoever, express or implied, including without limitation any implied warranties of merchantability or fitness for a particular purpose, of non-infringement, or regarding results obtained through the use of any product, whether arising from a statute or otherwise in law or from a course of performance, dealing or usage of trade.