GCG ELISA kit (Mouse)

Category: Assay Kits
Catalog
CEB266Mu
(Ships in 5-10 business days)

Questions? Contact us

Call (800) 832-2611

arp-guarantee
- +
$0.00
More Information
Product Name GCG ELISA kit (Mouse)
Description This assay has high sensitivity and excellent specificity for detection of Glucagon (GC). No significant cross-reactivity or interference between Glucagon (GC) and analogues was observed.
Synonyms GC; GLP1; GLP2; GRPP; Glicentin-Related Polypeptide; Glucagen; Oxyntomodulin; Incretin hormone
Method Competitive
Detection Range 18.52-1,500pg/mL
Sensitivity 7.47pg/mL
Target GCG
Specificity This assay has high sensitivity and excellent specificity for detection of Glucagon (GCG). No significant cross-reactivity or interference between Glucagon (GCG) and analogues was observed.
Reactivity Mouse
Sample Types Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates And Other Biological Fluids
Reconstitution 1.Prepare all reagents, samples and standards; 2.Add 50uL standard or sample to each well. And then add 50uL prepared Detection Reagent A immediately. Shake and mix.Incubate 1 hour at 37℃; 3.Aspirate and wash 3 times; 4.Add 100uL prepared Detection Reagent B.Incubate 30 minutes at 37℃; 5.Aspirate and wash 5 times; 6.Add 90uL Substrate Solution.Incubate 10-20 minutes at 37℃; 7.Add 50uL Stop Solution.Read at 450 nm immediately.
Uniprot P55095
Storage 4°C for 1 month/ -20°C for long-term(within shelf life)
Notes Colormetric
References PER2 promotes glucose storage to liver glycogen during feeding and acute fasting by inducing Gys2 PTG and GL expression;IL-21 is a major negative regulator of IRF4-dependent lipolysis affecting Tregs in adipose tissue and systemic insulin sensitivity;Enzogenol improves diabetes-related metabolic change in C57BL/KsJ-db/db?mice, a model of type 2 diabetes mellitus;Subcutaneous administration of liraglutide ameliorates learning and memory impairment by modulating tau hyperphosphorylation via the glycogen synthase kinase-3 pathway in an amyloid protein induced alzheimer disease mouse model;Subcutaneous liraglutide ameliorates methylglyoxal-induced Alzheimer-like tau pathology and cognitive impairment by modulating tau hyperphosphorylation and glycogen synthase kinase-3β.;Ginsenoside Rg5 attenuates hepatic glucagon response via suppression of succinate-associated HIF-1α induction in HFD-fed mice;Effects of Acute Cold Stress on Liver O-GlcNAcylation and Glycometabolism in Mice;Regulating glycolysis, the TLR4 signal pathway and expression of RBM3 in mouse liver in response to acute cold exposure;Effects of Cold-inducible RNA-binding Protein (CIRP) on Liver Glycolysis during Acute Cold Exposure in C57BL/6 Mice;In vitro expansion of pancreatic islet clusters facilitated by hormones and chemicals;Mice with nucleus tractus solitarius injury induced by chronic restraint stress present impaired ability to raise blood glucose and glucagon levels when blood glucose …;Acarbose ameliorates spontaneous type‑2 diabetes in db/db mice by inhibiting PDX‑1 methylation;Mof acetyltransferase inhibition ameliorates glucose intolerance and islet dysfunction of type 2 diabetes via targeting pancreatic α-cells;
Supplier Cloud Clone

PROTOCOLS:

All Research Products are sold for laboratory RESEARCH USE ONLY and ARE NOT TO BE USED FOR HUMAN OR ANIMAL THERAPEUTIC OR DIAGNOSTIC APPLICATIONS. The information presented is believed to be accurate; however, said information and products are offered without warranty or guarantee since the ultimate conditions of use and the variability of the materials treated are beyond our control. Nothing disclosed herein is to be construed as a recommendation to use our products in violation of any patents. ARP American Research Products, Inc. does not submit its products for regulatory review by any government body or other organization, and we do not validate them for clinical, therapeutic or diagnostic use, or for safety and effectiveness. You are solely responsible for making sure that the way you use the products complies with applicable laws, regulations and governmental policies and for obtaining all necessary approvals, intellectual property rights, licenses and permissions that you may need related to your use. Under no circumstances shall ARP American Research Products, Inc. be liable for damages, whether consequential, compensatory, incidental or special, strict liability or negligence, breach of warranty or any other theory arising out of the use of the products available from ARP American Research Products, Inc. Nothing contained herein warrants that the use of the products will not infringe on the claims of any patents covering the product itself or the use thereof in combination with other products or in the operation of any process. ARP American Research Products, Inc. disclaims any and all representations or warranties of any kind whatsoever, express or implied, including without limitation any implied warranties of merchantability or fitness for a particular purpose, of non-infringement, or regarding results obtained through the use of any product, whether arising from a statute or otherwise in law or from a course of performance, dealing or usage of trade.