Goat anti-Neuro-d4 / DPF1 Antibody

Category: Antibodies
Catalog
EB05827
(Ships in 5-10 business days)

Questions? Contact us

Call (800) 832-2611

arp-guarantee
- +
$0.00
More Information
Product Name Goat anti-Neuro-d4 / DPF1 Antibody
Synonyms DPF1; NEUD4; neuro-d4; D4, zinc and double PHD fingers family 1; Neuro-d4 (rat) homolog; D4, zinc and double PHD fingers, family 1; MGC150428; MGC150429; BAF45b; OTTHUMP00000211615; neuro-d4 homolog
Host Goat
Clonality Polyclonal
Conjugate Unconjugated
Immunogen C-HLKEKASAYITLT
Molecular Weight 46.8; 42.5; 37.9
Target Neuro-d4 / DPF1
Amino Acid Sequence HLKEKASAYITLT
Reactivity Bovine, Human, Mouse, Rat
Applications ELISA, IF
Working Dilutions Peptide ELISA: antibody detection limit dilution 1:2000.
Form Liquid, in Tris saline, 0.02% sodium azide, pH7.3 with 0.5% bovine serum albumin
Diluent Buffer Supplied at 0.5 mg/ml in Tris saline, 0.02% sodium azide, pH 7.3 with 0.5% bovine serum albumin. Aliquot and store at -20°C. Minimize freezing and thawing.
Reconstitution WB: Preliminary experiments showed a band at approx 38-40kDa in Human Cerebellum and Frontal Cortex lysates after 0.3-1µg/ml antibody staining (calculated MW of 37.9kDa according to NP_001128628.1. Primary incubation 1 hour at room temperature.. Notes: Immunofluorescence: Strong expression of the protein seen in the nuclei and weaker staining in the cytoplasm of MCF7 and U2OS cells. Recommended concentration: 10µg/ml.
Gene Id Human GeneIDs: 8193. Non-Human GeneIDs: 29861 (mouse); 50545 (rat);
Storage Aliquot and store at -20°C. Minimize freezing and thawing.
References Chestkov AV, Baka ID, Kost MV, Georgiev GP, Buchman VL. , The d4 gene family in the human genome., Genomics. 1996 Aug 15;36(1):174-7., PMID: 8812431
Supplier Everest Biotech

All Research Products are sold for laboratory RESEARCH USE ONLY and ARE NOT TO BE USED FOR HUMAN OR ANIMAL THERAPEUTIC OR DIAGNOSTIC APPLICATIONS. The information presented is believed to be accurate; however, said information and products are offered without warranty or guarantee since the ultimate conditions of use and the variability of the materials treated are beyond our control. Nothing disclosed herein is to be construed as a recommendation to use our products in violation of any patents. ARP American Research Products, Inc. does not submit its products for regulatory review by any government body or other organization, and we do not validate them for clinical, therapeutic or diagnostic use, or for safety and effectiveness. You are solely responsible for making sure that the way you use the products complies with applicable laws, regulations and governmental policies and for obtaining all necessary approvals, intellectual property rights, licenses and permissions that you may need related to your use. Under no circumstances shall ARP American Research Products, Inc. be liable for damages, whether consequential, compensatory, incidental or special, strict liability or negligence, breach of warranty or any other theory arising out of the use of the products available from ARP American Research Products, Inc. Nothing contained herein warrants that the use of the products will not infringe on the claims of any patents covering the product itself or the use thereof in combination with other products or in the operation of any process. ARP American Research Products, Inc. disclaims any and all representations or warranties of any kind whatsoever, express or implied, including without limitation any implied warranties of merchantability or fitness for a particular purpose, of non-infringement, or regarding results obtained through the use of any product, whether arising from a statute or otherwise in law or from a course of performance, dealing or usage of trade.