Hepc ELISA kit (Human)

Category: Assay Kits
Catalog
CEB979Hu
(Ships in 5-10 business days)

Questions? Contact us

Call (800) 832-2611

arp-guarantee
- +
$0.00
More Information
Product Name Hepc ELISA kit (Human)
Description This assay has high sensitivity and excellent specificity for detection of Hepcidin (Hepc). No significant cross-reactivity or interference between Hepcidin (Hepc) and analogues was observed.
Synonyms HAMP; HFE2B; PLTR; LEAP1; Hepcidin Antimicrobial Peptide; Liver-expressed antimicrobial peptide 1; Putative liver tumor regressor
Method Competitive
Detection Range 320-200,000pg/mL
Sensitivity 112pg/mL
Target Hepc
Specificity This assay has high sensitivity and excellent specificity for detection of Hepcidin (Hepc). No significant cross-reactivity or interference between Hepcidin (Hepc) and analogues was observed.
Reactivity Human
Sample Types Serum, Plasma, Tissue Homogenates, Cell Lysates, Cell Culture Supernates And Other Biological Fluids
Reconstitution 1.Prepare all reagents, samples and standards; 2.Add 50uL standard or sample to each well. And then add 50uL prepared Detection Reagent A immediately. Shake and mix.Incubate 1 hour at 37℃; 3.Aspirate and wash 3 times; 4.Add 100uL prepared Detection Reagent B.Incubate 30 minutes at 37℃; 5.Aspirate and wash 5 times; 6.Add 90uL Substrate Solution.Incubate 10-20 minutes at 37℃; 7.Add 50uL Stop Solution.Read at 450 nm immediately.
Uniprot P81172
Storage 4°C for 1 month/ -20°C for long-term(within shelf life)
Notes Colormetric
References Serum iron metabolism markers including hepcidin in multiple sclerosis patients;Monitoring Hepcidin Level in Chronic Hepatitis C Virus Patients during Therapy;Hepcidin and regulation of iron homeostasis in maintenance hemodialysis patients;The interplay among iron metabolism, endothelium and inflammatory cascade in dysmetabolic disorders;An Evaluation of the Correlation between Hepcidin Serum Levels and Disease Activity in Inflammatory Bowel Disease;Serum hepcidin levels in Bulgarian population.;Liver Congestion in Heart Failure Contributes to Inappropriately Increased Serum Hepcidin despite Anemia;Hepcidin regulation in prostate and its disruption in prostate cancer;Effect of a More Permeable Dialysis Membrane on ESA Resistance in Hemodialysis Patients - A Pilot Investigation;Urinary Hepcidin in Diagnosis of Iron Deficiency Anemia;Hepcidin in tumor‐related iron deficiency anemia and tumor‐related anemia of chronic disease: pathogenic mechanisms and diagnosis;The Effects of Treatment on Serum Hepcidin and Iron Homeostasis in HIV-1-Infected In-dividuals;Hydrogen sulfide attenuates inflammatory hepcidin by reducing IL-6 secretion and promoting SIRT1-mediated STAT3 deacetylation;Acidic Polysaccharide from Angelica sinensis Reverses Anemia of Chronic Disease Involving the Suppression of Inflammatory Hepcidin and NF-κB Activation;Evaluation of a competitive hepcidin ELISA assay in the differential diagnosis of iron deficiency anaemia with concurrent inflammation and anaemia of inflammation in elderly patients;AMPK serves as a Therapeutic Target against Anemia of Inflammation;Hepcidin suppression in β‑thalassemia is associated with the down‑regulation of atonal homolog 8;Modulation of iron status biomarkers in tuberculosis-diabetes co-morbidity;The Role of Insulin Therapy in Correcting Hepcidin Levels in Patients with Type 2 Diabetes Mellitus.;Increased NGAL level associated with iron store in chronic kidney disease with anemia;Relationship between obesity and iron deficiency anemia: is there a role of hepcidin?;Hepcidin serum levels in HCV chronically mono-infected naïve patients, compared to healthy individuals;Increased Hepcidin Levels During a Period of High Training Load Do Not Alter Iron Status in Male Elite Junior Rowers;Can Calprotectin Show Subclinical Inflammation in Familial Mediterranean Fever Patients?;Circulating Osteocyte‐Related Biomarkers (vitamin D, sclerostin, dickkopf-1), hepcidin, and oxidative stress markers in early breast cancer: their impact in …;Urinary hepcidin concentration in assessment of iron homeostasis in pediatrics;COMPARATIVE MONITORING OF THE ENZYME ACTIVITY OF BONE METABOLISM IN PATIENTS AFTER DENTAL IMPLANTATION;Serum iron, prealbumin, D-dimer and prothrombin time are indicators of the diagnosis, severity and outcome of Salmonella enterica serovar Enteritidis infection;Гепсидин и индекс фиброза печени MELD-XI как маркеры полиорганной недостаточности у пациентов хронической сердечной недостаточностью с …;Ассоциации уровней NT-proBNP и гепсидина с клинико-лабораторными параметрами у больных хронической сердечной недостаточностью с разной …;Correlation of hepcidin and serum ferritin levels in thalassemia patients at Chiang Mai University Hospital;Continuous Veno-Venous Hemofiltration (CVVH) Improves Iron Metabolism Disorders in Patients With Sepsis: A Single-Center Prospective Cohort Study;Evaluation of Serum Cyclooxygenase, Hepcidin Levels in Acute Renal Injury (AKI) Patients Following Cardiac Catheterization;Caffeine and alcohol-friends or foes of human iron stores?;Serum Calprotectin and Iron Metabolism Biomarker Levels in Behçet's Disease;
Supplier Cloud Clone

PROTOCOLS:

All Research Products are sold for laboratory RESEARCH USE ONLY and ARE NOT TO BE USED FOR HUMAN OR ANIMAL THERAPEUTIC OR DIAGNOSTIC APPLICATIONS. The information presented is believed to be accurate; however, said information and products are offered without warranty or guarantee since the ultimate conditions of use and the variability of the materials treated are beyond our control. Nothing disclosed herein is to be construed as a recommendation to use our products in violation of any patents. ARP American Research Products, Inc. does not submit its products for regulatory review by any government body or other organization, and we do not validate them for clinical, therapeutic or diagnostic use, or for safety and effectiveness. You are solely responsible for making sure that the way you use the products complies with applicable laws, regulations and governmental policies and for obtaining all necessary approvals, intellectual property rights, licenses and permissions that you may need related to your use. Under no circumstances shall ARP American Research Products, Inc. be liable for damages, whether consequential, compensatory, incidental or special, strict liability or negligence, breach of warranty or any other theory arising out of the use of the products available from ARP American Research Products, Inc. Nothing contained herein warrants that the use of the products will not infringe on the claims of any patents covering the product itself or the use thereof in combination with other products or in the operation of any process. ARP American Research Products, Inc. disclaims any and all representations or warranties of any kind whatsoever, express or implied, including without limitation any implied warranties of merchantability or fitness for a particular purpose, of non-infringement, or regarding results obtained through the use of any product, whether arising from a statute or otherwise in law or from a course of performance, dealing or usage of trade.