| Product Name | Bovine Peptidyl-prolyl cis-trans isomerase D (PPID) ELISA Kit |
|---|---|
| Description | Bovine Peptidyl-prolyl cis-trans isomerase D (PPID) ELISA Kit has high sensitivity and excellent specificity for detection of Bovine PPID. No significant cross-reactivity or interference between Bovine PPID and analogues was observed. Cyclophilin D, which is located in the matrix of mitochondria, is a component of the mitochondrial permeability transition pore. The pore opening raises the permeability of the mitochondrial inner membrane, allows influx of cytosolic molecules into the mitochondrial matrix, increases the matrix volume, and disrupts the mitochondrial outer membrane. As a result, the mitochondria fall into a functional disorder, so the opening of the pore plays an important role in cell death. Cyclophilin D is thought to regulate the opening of the pore because cyclosporin, which binds to CyP-D, inhibits the pore opening. Cyclophilin-40 (CyP40, also CYPD) was identified by Kieffer et al. (1992) as a 40-kD cyclophilin-like protein with PPIase activity. In the bovine uterus, CyP40 is a component of the estrogen receptor complex. This Bovine Peptidyl-prolyl cis-trans isomerase D (PPID) ELISA Kit employs a two-site sandwich ELISA to quantitate PPID in samples. An antibody specific for PPID has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyPPID present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for PPID is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of PPID bound in the initial step. The color development is stopped and the intensity of the color is measured. |
| Synonyms | PPID, CYP-40, CYPD, MGC33096, 40 kDa peptidyl-prolyl cis-trans isomerase D, PPIase, cyclophilin 40, cyclophilin D, cyclophilin-related protein, rotamase |
| Method | Sandwich ELISA |
| Detection Range | Please inquire |
| Sensitivity | Please inquire |
| Reactivity | Bovine |
| Sample Types | Cell culture supernatants, Serum, Plasma, Other biological fluids |
| Gene Id | 281420 |
| Storage | 2-8°C |
| Background |
Cyclophilin D, which is located in the matrix of mitochondria, is a component of the mitochondrial permeability transition pore. The pore opening raises the permeability of the mitochondrial inner membrane, allows influx of cytosolic molecules into the mitochondrial matrix, increases the matrix volume, and disrupts the mitochondrial outer membrane. As a result, the mitochondria fall into a functional disorder, so the opening of the pore plays an important role in cell death. Cyclophilin D is thought to regulate the opening of the pore because cyclosporin, which binds to CyP-D, inhibits the pore opening. Cyclophilin-40 (CyP40, also CYPD) was identified by Kieffer et al. (1992) as a 40-kD cyclophilin-like protein with PPIase activity. In the bovine uterus, CyP40 is a component of the estrogen receptor complex. |
| Supplier | Abbkine |
All Research Products are sold for laboratory RESEARCH USE ONLY and ARE NOT TO BE USED FOR HUMAN OR ANIMAL THERAPEUTIC OR DIAGNOSTIC APPLICATIONS. The information presented is believed to be accurate; however, said information and products are offered without warranty or guarantee since the ultimate conditions of use and the variability of the materials treated are beyond our control. Nothing disclosed herein is to be construed as a recommendation to use our products in violation of any patents. ARP American Research Products, Inc. does not submit its products for regulatory review by any government body or other organization, and we do not validate them for clinical, therapeutic or diagnostic use, or for safety and effectiveness. You are solely responsible for making sure that the way you use the products complies with applicable laws, regulations and governmental policies and for obtaining all necessary approvals, intellectual property rights, licenses and permissions that you may need related to your use. Under no circumstances shall ARP American Research Products, Inc. be liable for damages, whether consequential, compensatory, incidental or special, strict liability or negligence, breach of warranty or any other theory arising out of the use of the products available from ARP American Research Products, Inc. Nothing contained herein warrants that the use of the products will not infringe on the claims of any patents covering the product itself or the use thereof in combination with other products or in the operation of any process. ARP American Research Products, Inc. disclaims any and all representations or warranties of any kind whatsoever, express or implied, including without limitation any implied warranties of merchantability or fitness for a particular purpose, of non-infringement, or regarding results obtained through the use of any product, whether arising from a statute or otherwise in law or from a course of performance, dealing or usage of trade.